Purpose: This study was conducted to develop national indication-based DRL values for common indications of adult computed tomography (CT) examinations for clinical application in Ghana. Materials and methods: The methodological approach recommended by the International Commission on Radiological Protection (ICRP), Publication 135, for the development of DRLs, was employed. Studies on CT infrastructure, common indications and quality control tests were first undertaken. A sample of 20 CT dose descriptor/quantity data sets were collected from each centre for each indication. Overall, 3960 data sets were collected for all identified common indications from 71.4% of the total CT scanners in Ghana (25/35). The data were collected from image folders reported and accepted by radiologists. The objective image quality was assessed through a signal to noise ratio (SNR) analysis prior to using the data and extracting DRL values. Results: Clinical indications and their respective DRL values in terms of volume weighted CT dose index (CTDIvol) and dose length product (DLP) were cerebrovascular accident (CVA)/stroke (77 mGy; 1313 mGy.cm), head trauma/injury (76 mGy; 1596 mGy.cm), brain tumour/space occupying lesion (SOL) (77 mGy; 2696 mGy.cm), lung tumour/cancer (12 mGy; 828 mGy.cm) and chest lesion with chronic kidney disease (CKD) (13 mGy; 467 mGy.cm). Others were abdominopelvic lesion (17 mGy; 1299 mGy.cm), kidney stones (15 mGy; 731 mGy.cm), urothelial malignancy/CT-intravenous urogram (CT-IVU) (11 mGy; 1449 mGy.cm) and pulmonary embolism (PE) (14 mGy; 942 mGy.cm). Conclusion: National Indication-based DRL values developed in this study are recommended to be used to manage CT radiation dose in Ghana.
Original language | English |
---|---|
Pages (from-to) | 274-284 |
Number of pages | 11 |
Journal | Physica Medica |
Volume | 84 |
DOIs | |
Publication status | Published - Apr 2021 |
Keywords
- Computed tomography
- Diagnostic Reference Levels (DRLs)
- Ghana
- Indication-based DRLs
- Optimisation